Boiler Drain Valves
MODEL:
- LBM 23
- LBM 24
- LBM 24A
Warning & Notes
Turn off the water supply and release system pressure and allow hot water to cooling before installation.
Dimension (mm)
| Model | H | L | l1 |
|---|---|---|---|
| LBM 23 | 90.1 | 53.1 | 27.5 |
| LBM 24 | 91.1 | 53.1 | 27.5 |
| LBM 24A | 91.1 | 53.1 | 27.5 |
Installation
- Apply PTFE (Teflon) thread seal tape clockwise around the male pipe threads 5 to 6 times
- Thread the valve onto the pipe by hand. Use a wrench on the flats of the brass body and tighten securely
- Rotate the valve until the hose connection points right. Do not over- tighten
- Close the hand whee on the water supply a connections for leaks
Maintenance
Leakage Around the Stem (Below Hand-wheel):
Slightly tighten the packing nut (approximately 1/8 turn) with a wrench. Do not over-tighten.
Valve Fails to Shut Off Completely (Persistent Dripping):
Isolate the water supply, remove the bonnet assembly, and inspect the seat washer. Clean or replace the washer as necessary
Tools Required
- Adjustable Wrench or Pipe Wrench
- PTFE (Teflon) thread seal tap