Angle Stop Valves
MODEL:
- LCA 1A
Warning & Notes
Turn off the water supply and release system pressure before installation.
Dimension (mm)
| Model | H | L | L1 | D |
|---|---|---|---|---|
| LCA 1A | 57.5 | 36.5 | 20.5 | 51.2 |
Installation
- Install the inlet using a PEX fitting that fits properly
- Assembling the Outlet Joint pipe using a compression ring and tighten it securely
- Close the handle firmly. Slowly turn on the water supply and inspect all connections for leaks
Maintenance
Leakage Around the Stem (Below Handle):
Slightly tighten the packing nut (approximately 1/8 turn) with a wrench. Do not over-tighten.
Valve Fails to Shut Off Completely (Persistent Dripping):
Isolate the water supply, remove the bonnet assembly, and inspect the seat washer. Clean or replace the washer as necessary.
Tools Required
- Adjustable Wrench or Pipe Wrench